Thanya Parametthanuwat. Heat transfer characteristic of advanced loop thermosyphon with check value (ALTCV) containing nanofluids. (). King Mongkut University of Technology North Bangkok. Central Library. : , 2014.
Heat transfer characteristic of advanced loop thermosyphon with check value (ALTCV) containing nanofluids
Abstract:
This report is focus on heat transfer characteristic advanced loop thermosyphon with check
value (ALT/CV) containing nanofluids. It will highlight theories for investigating heat transfer
characteristic. Points of importance will be emphasize, with significance given to the heat transfer
characteristics of ALT/CV and their use in this experiment. The chapter I present work aims to study
the effects of operating temperature, loop and check valve on thermal performance of nanofluids in an
ALT/CV. The chapter II present theoretical consideration to study the thermosyphon, heat transfer
characteristics, dimensionless, nanofluids and surfactant. The chapter III describes the results and
discussions of silver nanofluids properties when preparing for filled as working fluids in ALT/CV. It
is divided into a number of sections to determine the thermal properties of silver nanofluids
containing surfactant. The chapter IV describes the heat transfer rate behaviour of an advanced loop
thermosyphon with check valve(ALT/CV) which is filled with silver nanofluids and containing oleic
surfactant (OA) and potassium oleate surfactant (OAK+). Also included are the explanation of
dimensionless and the behaviour characteristics in the ALT/CV. The filling ratios are 30, 50 and 80%
with respect to evaporator volume. The heat was supplied of 20%, 40%, 60%, 80% and 100% of
heater (2,000 Watt). Five working fluids are: deionized water, deionized water based silver
nanoparticles concentration of 0.5 wt% (NP), NP containing 0.5, 1 and 1.5 wt% of OA and OAK+
respectively. The dimensionless parameters on ALT/CV are such as size (LO size)/Di ,
Pr, Bo, Ja, Co, Cd, Gam, Pem, Ar, Gr and Z . Then, all of dimensionless was to create a
correlation equation with Kutaeladze number for predicting heat transfer of ALT/CV, shows as
below;
q = 3.24 [ LOsize6 . Pr6.2 . Bo6.4 . Ja6.2 . Co5.2 . Cd3.8 . Gam1.5 ]1.57 / Di Pem2.7 . Ar0.4 . Z0.2 . Gr0.6 x [pvhfg (pv pl)]0.25 / (pv)
The correlation equation is used to calculate and construct a design for the oven installed with
ALT/CV (OALT/CV) shows in Chapter V.