Abstract:
Performance of PV/T a system for producing electricity and thermal energy using water as a heat transfer media was investigated in this study. The system consists of PV/T collector having an area of 0.79 square meters, storage tank with 80 liters of water, small water pump, water flow rate controller, battery charge controller, and battery. The PV/T collector system was installed on the roof of faculty of engineering building (N13.735558 E100.533257) Chulalongkorn University, Bangkok Thailand. The PV/T collector was installed at a 15 degree to the floor plain and facing to the south. The test was conducted in October 2012. The parameters are solar intensity, initial and final water temperature in storage tank, inlet and outlet water temperature from PV/T collector, and ambient temperature. During the test, the water flow rate was set constant at 1.2 liters/minute. All parameters were collected every 2 minutes during 8:00 AM to 4:00 PM for 10 days by using an automatic data logger. The parameters used to analyze the electric power were voltage and electric current from battery using wire wound resistance and then multiplied with time (hr) to achieve electric energy. The analysis result, average daily thermal efficiency is 40.9%, average daily electricity efficiency is 3.0%, and average daily overall efficiency is 43.9%. respectively upon using statistic data of solar intensity and outdoor temperature in 2010, the predicted electrical energy and thermal energy from the PV/T system would be 78 wh/day and 1,181 wh/day at water temperature of 41.7˚C, respectively.